Showing 1–12 of 18 results

Email
OHM
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor
  • Type of mounting: Lateral mounting(External only)
  • Cooling capacity : 300/350W ~ 2100/2300W
  • Rated volage(50/60Hz): Single phase 200VAC, Three phase 200VAC
  • Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
  • Maintenance reminder, Forced cooling operation for inspection
  • Certificates/Approvals : EU RoHS2, CE
  • Part number:

OCA-H350BCD-AW2

OCA-H700BCD-AW2

OCA-H1300BCD-A200

OCA-H2300BCD-AW2

Note

* Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
* Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)

Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor
  • Type of mounting: Lateral mounting
  • Cooling capacity : 280 / 300W ~ 650/800W
  • Rated volage(50/60Hz): Single phase 200~240VAC
  • Function: Off-temperature alarm, Detection of abnormal heat dissipation,
  • Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
  • Certificates/Approvals : EU RoHS2, CE
  • Part Number:

OCA-H300BCS-A200        OCA-H800BCS-A200

OCA-H500BCS-A200        OCA-H800BCS-A220

OCA-H500BCS-A220        OCA-H800BCS-A230

OCA-H500BCS-A230        OCA-H800BCS-A240

OCA-H500BCS-A240

Note
  • Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
  • Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor
  • Type of mounting: Lateral mounting
  • Cooling capacity : 250/300W ~ 2600/2900W
  • Rated volage(50/60Hz): Single phase 200~240VAC
  • Communication function: RS485 (Modbus / RTU)
  • Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
  • Maintenance reminder, Forced cooling operation for inspection
  • Certificates/Approvals : EU RoHS2, CE
  • Part Number:

OCA-H300BC-AW2

OCA-H600BC-AW2

OCA-H1000BC-AW2

OCA-H1600BC-AW2

OCA-H2200BC-AW2

OCA-H2900BC-AW2

Note
  • Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
  • Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
  • Relating products:

 

 

Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor
  • Type of mounting: Roof mounting
  • Cooling capacity : 300/350W ~ 2700/3000W
  • Rated volage(50/60Hz): Single phase 200~240VAC
  • Communication function: RS485 (Modbus / RTU)
  • Function:

Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,

Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up.

  • Certificates/Approvals : EU RoHS2, CE
  • Part number: OCA-S300AC-A100
Note
  • Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
  • Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-E series
  • High collection capability by ionizing mist!
  • Suitable for both oil and water-soluble mists
  • Max. air flow :8 / 10m3/min~ 40/45m3/min
  • Collection efficiency:Min. 99% (by gravimetric method)
  • Max. oil mist density :300mg3/min
  • Rated voltage:3-phase, 200 VAC 50/60 Hz
  • Suction port diameter:Ø148mm~Ø200mm
  • Certificates/Approvals: EU RoHS
Note
  • Working temperature : 0 to +40℃
  • Max. suction air temp : +40℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-F series, Filter
  • 99.8 % or higher collection rate! Low cost, high performance and energy saving
  • Max. air flow : 4.2/5m3/min~18/20m3/min
  • Collection efficiency:Min. 99.8% (by gravimetric method)
  • Rated voltage:3-phase, 200VAC 50/60Hz
  • Suction port diameter:Ø100mm~Ø150mm
  • Certificates/Approvals: EU RoHS2
Note
  • Working temperature : 0 to +40℃
  • Max. suction air temp : +50℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-11 series, Filter
  • Energy saving yet high power!
  • Designed small and light weight
  • Eliminates filter replacement and industrial waste
  • Max. air flow :8/10m3/min
  • Collection efficiency:Min. 83%±5% Particle diameter 2µm or larger
  • Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
  • Suction port diameter:Ø123mm
  • Certificates/Approvals: EU RoHS
Note
  • Working temperature : 0 to +40℃
  • Max. suction air temp : +50℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-N2 series
  • Super high collection efficiency as Non-Filter!
  • Eliminates filter replacement and industrial waste
  • Max. air flow :4.5/5.0m3/min~ 21.5/24.5m3/min
  • Collection efficiency:Min. 99% Particle diameter 2µm or larger
  • Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
  • Suction port diameter:Ø98mm~Ø198mm
  • Certificates/Approvals: EU RoHS2
Note
  • Working temperature : 0 to +40℃
  • Max. suction air temp : +80℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, ODU-DSA, Laser maker, High pressure type
  • Eliminates fumes generated in soldering or laser marking process
  • Suitable for clean rooms
  • Max. air volume: 2.2 m3/min ~3.2m3/min
  • Max. static pressure:9.1 kPa~ 9.5kPa
  • Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
  • Rated voltage (50/60Hz): Single phase, 100VAC
  • Max. intake temperature: +40℃
  • Certificates/Approvals: EU RoHS2
Note
  • Working temperature : 0 to +40℃
  • Max. intake temperature : +40℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High pressure type
  • Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
  • Max. air volume: 2.2 m3/min~5.5 m3/min
  • Max. static pressure: 9.1 kPa~13.5 kPa
  • Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
  • Rated voltage (50/60Hz): Single phase, 100VAC,200VAC
  • Max. intake temperature: +40℃
  • Certificates/Approvals: EU RoHS
Note
  • Working temperature : 0 to +40℃
  • Max. intake temperature : +40℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High Volume, ODU-HC
  • Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
  • Max. air volume: 2.9m3/min ~7.0 m3/min
  • Max. static pressure: 2.5kPa ~2.9kPa
  • Collection efficiency: Min. 99% (for 0.3μm or larger particles)
  • Rated voltage (50/60Hz): Single phase, 100VAC ・Max. intake temperature: +40℃
  • Certificates/Approvals : EU RoHS
Note
  • Working temperature : 0 to +40℃
  • Max. intake temperature : +40℃
Salient features
  • Classification: OHM electric, OHM Distributor, OHM Electric Distributor, General Environments, High Volume, Laser marker, OSK-ACC
  • Suitable for laser markers of short time operation and low viscosity fumes in general environments
  • Max. air volume: 2.8 m3/min
  • Max. static pressure: 2.5 kPa
  • Collection efficiency: Min.99% (for 0.3μm or larger particles)
  • Rated voltage (50/60Hz): Single phase, 100VAC
  • Certificates/Approvals : EU RoHS2
Note
  • Working temperature : 0 to +40℃
  • Max. intake temperature : +40℃