- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-11 series, Filter
- Energy saving yet high power!
- Designed small and light weight
- Eliminates filter replacement and industrial waste
- Max. air flow :8/10m3/min
- Collection efficiency:Min. 83%±5% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø123mm
- Certificates/Approvals: EU RoHS
Non-filter oil mist collector OMC-11_OHM Distributor
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
Related products
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-F series, Filter
- 99.8 % or higher collection rate! Low cost, high performance and energy saving
- Max. air flow : 4.2/5m3/min~18/20m3/min
- Collection efficiency:Min. 99.8% (by gravimetric method)
- Rated voltage:3-phase, 200VAC 50/60Hz
- Suction port diameter:Ø100mm~Ø150mm
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Roof mounting
- Cooling capacity : 300/350W ~ 2700/3000W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function:
Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up.
- Certificates/Approvals : EU RoHS2, CE
- Part number: OCA-S300AC-A100
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
Machinery/ Industrial Equipment

Non-fluorocarbon Series Standard type Lateral mounting_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting
- Cooling capacity : 250/300W ~ 2600/2900W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
- Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part Number:
OCA-H300BC-AW2
OCA-H600BC-AW2
OCA-H1000BC-AW2
OCA-H1600BC-AW2
OCA-H2200BC-AW2
OCA-H2900BC-AW2
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Relating products:
Machinery/ Industrial Equipment
Electrostatic oil mist collector OMC-E series_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-E series
- High collection capability by ionizing mist!
- Suitable for both oil and water-soluble mists
- Max. air flow :8 / 10m3/min~ 40/45m3/min
- Collection efficiency:Min. 99% (by gravimetric method)
- Max. oil mist density :300mg3/min
- Rated voltage:3-phase, 200 VAC 50/60 Hz
- Suction port diameter:Ø148mm~Ø200mm
- Certificates/Approvals: EU RoHS
- Working temperature : 0 to +40℃
- Max. suction air temp : +40℃
- Classification: OHM, OHM electric, OHM Distributor, OHM Electric Distributor, Motor, detector, OMD-3, OMD-2
- Detects voltage from three-phase induction motor. It electrically judges rotation and stop and outputs a signal.
- It can be detected simply by connecting two wires to the motor.
- Mounting method: DIN rail (35mm width) mounting
- Rated voltage (50 / 60Hz): AC100V or 200V
- Detection delay time: 0.2-1.5sec Variable depending on volume
- This detector is exclusively for AC200V three-phase induction motors. It cannot be used for single-phase commutator motors, etc.
- Certificates/Approvals : RoHS2
- Working temperature 0 to +55℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-N2 series
- Super high collection efficiency as Non-Filter!
- Eliminates filter replacement and industrial waste
- Max. air flow :4.5/5.0m3/min~ 21.5/24.5m3/min
- Collection efficiency:Min. 99% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø98mm~Ø198mm
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. suction air temp : +80℃
Machinery/ Industrial Equipment
For General Environments High volume type Laser marker use OSK-ACC_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, General Environments, High Volume, Laser marker, OSK-ACC
- Suitable for laser markers of short time operation and low viscosity fumes in general environments
- Max. air volume: 2.8 m3/min
- Max. static pressure: 2.5 kPa
- Collection efficiency: Min.99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Certificates/Approvals : EU RoHS2
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High Volume, ODU-HC
- Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
- Max. air volume: 2.9m3/min ~7.0 m3/min
- Max. static pressure: 2.5kPa ~2.9kPa
- Collection efficiency: Min. 99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC ・Max. intake temperature: +40℃
- Certificates/Approvals : EU RoHS
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃