- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting(External only)
- Cooling capacity : 300/350W ~ 2100/2300W
- Rated volage(50/60Hz): Single phase 200VAC, Three phase 200VAC
- Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
- Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part number:
OCA-H350BCD-AW2
OCA-H700BCD-AW2
OCA-H1300BCD-A200
OCA-H2300BCD-AW2
* Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
* Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
COOLCABI
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting
- Cooling capacity : 280 / 300W ~ 650/800W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Function: Off-temperature alarm, Detection of abnormal heat dissipation,
- Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part Number:
OCA-H300BCS-A200 OCA-H800BCS-A200
OCA-H500BCS-A200 OCA-H800BCS-A220
OCA-H500BCS-A220 OCA-H800BCS-A230
OCA-H500BCS-A230 OCA-H800BCS-A240
OCA-H500BCS-A240
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting
- Cooling capacity : 250/300W ~ 2600/2900W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
- Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part Number:
OCA-H300BC-AW2
OCA-H600BC-AW2
OCA-H1000BC-AW2
OCA-H1600BC-AW2
OCA-H2200BC-AW2
OCA-H2900BC-AW2
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Relating products:
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Roof mounting
- Cooling capacity : 300/350W ~ 2700/3000W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function:
Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up.
- Certificates/Approvals : EU RoHS2, CE
- Part number: OCA-S300AC-A100
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-E series
- High collection capability by ionizing mist!
- Suitable for both oil and water-soluble mists
- Max. air flow :8 / 10m3/min~ 40/45m3/min
- Collection efficiency:Min. 99% (by gravimetric method)
- Max. oil mist density :300mg3/min
- Rated voltage:3-phase, 200 VAC 50/60 Hz
- Suction port diameter:Ø148mm~Ø200mm
- Certificates/Approvals: EU RoHS
- Working temperature : 0 to +40℃
- Max. suction air temp : +40℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-F series, Filter
- 99.8 % or higher collection rate! Low cost, high performance and energy saving
- Max. air flow : 4.2/5m3/min~18/20m3/min
- Collection efficiency:Min. 99.8% (by gravimetric method)
- Rated voltage:3-phase, 200VAC 50/60Hz
- Suction port diameter:Ø100mm~Ø150mm
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-11 series, Filter
- Energy saving yet high power!
- Designed small and light weight
- Eliminates filter replacement and industrial waste
- Max. air flow :8/10m3/min
- Collection efficiency:Min. 83%±5% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø123mm
- Certificates/Approvals: EU RoHS
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
Factory
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-N2 series
- Super high collection efficiency as Non-Filter!
- Eliminates filter replacement and industrial waste
- Max. air flow :4.5/5.0m3/min~ 21.5/24.5m3/min
- Collection efficiency:Min. 99% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø98mm~Ø198mm
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. suction air temp : +80℃
ENVIRONMENTAL SOLUTION-DUST
For Clean Rooms High pressure type Laser marker use “ODU-DSA”_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, ODU-DSA, Laser maker, High pressure type
- Eliminates fumes generated in soldering or laser marking process
- Suitable for clean rooms
- Max. air volume: 2.2 m3/min ~3.2m3/min
- Max. static pressure:9.1 kPa~ 9.5kPa
- Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Max. intake temperature: +40℃
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
ENVIRONMENTAL SOLUTION-DUST
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High pressure type
- Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
- Max. air volume: 2.2 m3/min~5.5 m3/min
- Max. static pressure: 9.1 kPa~13.5 kPa
- Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC,200VAC
- Max. intake temperature: +40℃
- Certificates/Approvals: EU RoHS
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
ENVIRONMENTAL SOLUTION-DUST
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High Volume, ODU-HC
- Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
- Max. air volume: 2.9m3/min ~7.0 m3/min
- Max. static pressure: 2.5kPa ~2.9kPa
- Collection efficiency: Min. 99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC ・Max. intake temperature: +40℃
- Certificates/Approvals : EU RoHS
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
ENVIRONMENTAL SOLUTION-DUST
For General Environments High volume type Laser marker use OSK-ACC_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, General Environments, High Volume, Laser marker, OSK-ACC
- Suitable for laser markers of short time operation and low viscosity fumes in general environments
- Max. air volume: 2.8 m3/min
- Max. static pressure: 2.5 kPa
- Collection efficiency: Min.99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Certificates/Approvals : EU RoHS2
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃