- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High pressure type
- Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
- Max. air volume: 2.2 m3/min~5.5 m3/min
- Max. static pressure: 9.1 kPa~13.5 kPa
- Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC,200VAC
- Max. intake temperature: +40℃
- Certificates/Approvals: EU RoHS
For Clean Rooms High pressure type ODU-HP_OHM Distributor
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Related products
Machinery/ Industrial Equipment
For General Environments High volume type Laser marker use OSK-ACC_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, General Environments, High Volume, Laser marker, OSK-ACC
- Suitable for laser markers of short time operation and low viscosity fumes in general environments
- Max. air volume: 2.8 m3/min
- Max. static pressure: 2.5 kPa
- Collection efficiency: Min.99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Certificates/Approvals : EU RoHS2
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Machinery/ Industrial Equipment
For Clean Rooms High pressure type Laser marker use “ODU-DSA”_OHM Distributor
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, ODU-DSA, Laser maker, High pressure type
- Eliminates fumes generated in soldering or laser marking process
- Suitable for clean rooms
- Max. air volume: 2.2 m3/min ~3.2m3/min
- Max. static pressure:9.1 kPa~ 9.5kPa
- Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Max. intake temperature: +40℃
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting
- Cooling capacity : 280 / 300W ~ 650/800W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Function: Off-temperature alarm, Detection of abnormal heat dissipation,
- Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part Number:
OCA-H300BCS-A200 OCA-H800BCS-A200
OCA-H500BCS-A200 OCA-H800BCS-A220
OCA-H500BCS-A220 OCA-H800BCS-A230
OCA-H500BCS-A230 OCA-H800BCS-A240
OCA-H500BCS-A240
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Lateral mounting(External only)
- Cooling capacity : 300/350W ~ 2100/2300W
- Rated volage(50/60Hz): Single phase 200VAC, Three phase 200VAC
- Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
- Maintenance reminder, Forced cooling operation for inspection
- Certificates/Approvals : EU RoHS2, CE
- Part number:
OCA-H350BCD-AW2
OCA-H700BCD-AW2
OCA-H1300BCD-A200
OCA-H2300BCD-AW2
* Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
* Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
- Classification: OHM, OHM electric, OHM Distributor, OHM Electric Distributor, Motor, detector, OMD-3, OMD-2
- Detects voltage from three-phase induction motor. It electrically judges rotation and stop and outputs a signal.
- It can be detected simply by connecting two wires to the motor.
- Mounting method: DIN rail (35mm width) mounting
- Rated voltage (50 / 60Hz): AC100V or 200V
- Detection delay time: 0.2-1.5sec Variable depending on volume
- This detector is exclusively for AC200V three-phase induction motors. It cannot be used for single-phase commutator motors, etc.
- Certificates/Approvals : RoHS2
- Working temperature 0 to +55℃
- Classification: OHM, OHM machine, OHM electric, OHM Distributor, OHM Electric Distributor, Capcon, Liquidtight, cable gland, lineup
- OA-W series Wide Range:(Applicable to broad range of cable sizes!CTG and Metric screw type added, Applicable cable diameter Ø4 – 20mm)
- OA-W series Standard (Versatile product lineup different in color, applicable cable size or working condition, Applicable cable diameter Ø2 – 30mm)
- OA-W series Multiple (2 to 4 cables are clamped all at once. Saves both labor and space! Applicable cable diameter Ø1.7 – 7mm)
- OA-W series Slit (Slit rubber bushing enables clamping connector cables at entry/exit ports, Applicable cable diameter Ø2.2 – 20mm)
- OA-W series Splittable (For clamping and waterproofing a cable with connector, Applicable cable diameter Ø6 – 13mm)
- Protection category : IP 67
- Certificates/Approvals : EU RoHS2, (CE)
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Machinery/ Industrial Equipment
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-F series, Filter
- 99.8 % or higher collection rate! Low cost, high performance and energy saving
- Max. air flow : 4.2/5m3/min~18/20m3/min
- Collection efficiency:Min. 99.8% (by gravimetric method)
- Rated voltage:3-phase, 200VAC 50/60Hz
- Suction port diameter:Ø100mm~Ø150mm
- Certificates/Approvals: EU RoHS2
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Roof mounting
- Cooling capacity : 300/350W ~ 2700/3000W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function:
Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up.
- Certificates/Approvals : EU RoHS2, CE
- Part number: OCA-S300AC-A100
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)