- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, General Environments, High Volume, Laser marker, OSK-ACC
- Suitable for laser markers of short time operation and low viscosity fumes in general environments
- Max. air volume: 2.8 m3/min
- Max. static pressure: 2.5 kPa
- Collection efficiency: Min.99% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC
- Certificates/Approvals : EU RoHS2
For General Environments High volume type Laser marker use OSK-ACC_OHM Distributor
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Categories: ENVIRONMENTAL SOLUTION-DUST, Machinery/ Industrial Equipment, OHM
Related products
Salient features
- Classification: OHM, OHM machine, OHM electric, OHM Distributor, OHM Electric Distributor, Capcon, Liquidtight, cable gland, lineup
- OA-W series Wide Range:(Applicable to broad range of cable sizes!CTG and Metric screw type added, Applicable cable diameter Ø4 – 20mm)
- OA-W series Standard (Versatile product lineup different in color, applicable cable size or working condition, Applicable cable diameter Ø2 – 30mm)
- OA-W series Multiple (2 to 4 cables are clamped all at once. Saves both labor and space! Applicable cable diameter Ø1.7 – 7mm)
- OA-W series Slit (Slit rubber bushing enables clamping connector cables at entry/exit ports, Applicable cable diameter Ø2.2 – 20mm)
- OA-W series Splittable (For clamping and waterproofing a cable with connector, Applicable cable diameter Ø6 – 13mm)
Note
- Protection category : IP 67
- Certificates/Approvals : EU RoHS2, (CE)
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Machinery/ Industrial Equipment
Electrostatic oil mist collector OMC-E series_OHM Distributor
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-E series
- High collection capability by ionizing mist!
- Suitable for both oil and water-soluble mists
- Max. air flow :8 / 10m3/min~ 40/45m3/min
- Collection efficiency:Min. 99% (by gravimetric method)
- Max. oil mist density :300mg3/min
- Rated voltage:3-phase, 200 VAC 50/60 Hz
- Suction port diameter:Ø148mm~Ø200mm
- Certificates/Approvals: EU RoHS
Note
- Working temperature : 0 to +40℃
- Max. suction air temp : +40℃
Machinery/ Industrial Equipment
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, Clean room, High pressure type
- Suctions fine airborne dust with a large volume of air like a vent fan For clean room use
- Max. air volume: 2.2 m3/min~5.5 m3/min
- Max. static pressure: 9.1 kPa~13.5 kPa
- Collection efficiency: Min. 99.97% (for 0.3μm or larger particles)
- Rated voltage (50/60Hz): Single phase, 100VAC,200VAC
- Max. intake temperature: +40℃
- Certificates/Approvals: EU RoHS
Note
- Working temperature : 0 to +40℃
- Max. intake temperature : +40℃
Salient features
- Classification: OHM, OHM machine, OHM electric, OHM Distributor, OHM Electric Distributor, QUICK CAP, QUICKCAP, insulation cap, lineup
- Insulation cap for ring terminals OA-QM (Provides quick and high quality insulation to screw fastened terminals (for 3/4/5/6 mm)
- Insulation cap for ring terminals OA-QCM (Simply put cap on the screw fastened terminals for insulation (for 8, 10 mm))
- Multiple connection insulation cap OA-QTM for relaying (Convenient, terminal block and box in one. Eliminates troublesome taping work.)
- Multiple connection insulation cap OA-QTM for branching of power line (For branching power supply up to 600V, 30A and power lines)
Note
* Rated volted : 600V DC/AC
* Working temperature -20 ~+70℃ (80)
* Certificates/Approvals : EU RoHS2
Machinery/ Industrial Equipment
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-F series, Filter
- 99.8 % or higher collection rate! Low cost, high performance and energy saving
- Max. air flow : 4.2/5m3/min~18/20m3/min
- Collection efficiency:Min. 99.8% (by gravimetric method)
- Rated voltage:3-phase, 200VAC 50/60Hz
- Suction port diameter:Ø100mm~Ø150mm
- Certificates/Approvals: EU RoHS2
Note
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor
- Type of mounting: Roof mounting
- Cooling capacity : 300/350W ~ 2700/3000W
- Rated volage(50/60Hz): Single phase 200~240VAC
- Communication function: RS485 (Modbus / RTU)
- Function:
Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up.
- Certificates/Approvals : EU RoHS2, CE
- Part number: OCA-S300AC-A100
Note
- Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
- Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)
Machinery/ Industrial Equipment
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-N2 series
- Super high collection efficiency as Non-Filter!
- Eliminates filter replacement and industrial waste
- Max. air flow :4.5/5.0m3/min~ 21.5/24.5m3/min
- Collection efficiency:Min. 99% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø98mm~Ø198mm
- Certificates/Approvals: EU RoHS2
Note
- Working temperature : 0 to +40℃
- Max. suction air temp : +80℃
Machinery/ Industrial Equipment
Salient features
- Classification: OHM electric, OHM Distributor, OHM Electric Distributor, OMC-11 series, Filter
- Energy saving yet high power!
- Designed small and light weight
- Eliminates filter replacement and industrial waste
- Max. air flow :8/10m3/min
- Collection efficiency:Min. 83%±5% Particle diameter 2µm or larger
- Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
- Suction port diameter:Ø123mm
- Certificates/Approvals: EU RoHS
Note
- Working temperature : 0 to +40℃
- Max. suction air temp : +50℃