Showing 1–12 of 20 results

Email
Factory

Control Devices/FA Systems

Displacement Sensors / Measurement Sensors

Salient features
These Sensors can be used to measure distances and heights. A wide variety of models is available, including Laser Sensors, LED Sensors, Ultrasonic Sensors, Contact Sensors, Eddy Current Sensors, and more.
Note

High Precision Measurement Sensor
Displacement Sensors for Differentiation
Profile Measuring Sensors
Measurement Sensors
Other Displacement Sensors

Salient features
Safety Sensors detect workers entering hazardous areas and stop machines.
Note

Safety Light Curtains
Safety Multi-Light Beams
Single-beam Safety Sensors

Control Devices/FA Systems

Actuator

Salient features
Actuator products perform pick & place and other motions to support application construction.
Note

Delta robot
R6Y3
Pick and Place Solution. The fastest picking system integrated in the Sysmac platform

Salient features
*Type of mounting: Lateral mounting *Cooling capacity : 280 / 300W ~ 650/800W *Rated volage(50/60Hz): Single phase 200~240VAC *Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder,Forced cooling operation for inspection * Certificates/Approvals : EU RoHS2, CE
Note

* Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
* Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)

Salient features
*Type of mounting: Lateral mounting *Cooling capacity : 250/300W ~ 2600/2900W *Rated volage(50/60Hz): Single phase 200~240VAC * Communication function: RS485 (Modbus / RTU) *Function: Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection * Certificates/Approvals : EU RoHS2, CE
Note

* Working temperature : +20 to +50℃ ( Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max)
* Temp. setting range: +30 to +45℃ (Initial setting:+35℃) (Use only within the specified temperature range)

Salient features
* High collection capability by ionizing mist! * Suitable for both oil and water-soluble mists * Max. air flow :8 / 10m3/min~ 40/45m3/min * Collection efficiency:Min. 99% (by gravimetric method) * Max. oil mist density :300mg3/min * Rated voltage:3-phase, 200 VAC 50/60 Hz * Suction port diameter:Ø148mm~Ø200mm * Certificates/Approvals: EU RoHS
Note

* Working temperature : 0 to +40℃
* Max. suction air temp : +40℃

Salient features
* Super high collection efficiency as Non-Filter! * Eliminates filter replacement and industrial waste * Max. air flow :4.5/5.0m3/min~ 21.5/24.5m3/min * Collection efficiency:Min. 99% Particle diameter 2µm or larger * Rated voltage:3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz * Suction port diameter:Ø98mm~Ø198mm * Certificates/Approvals: EU RoHS2
Note

* Working temperature : 0 to +40℃
* Max. suction air temp : +80℃

Salient features
・Eliminates fumes generated in soldering or laser marking process Suitable for clean rooms ・Max. air volume: 2.2 m3/min ~3.2m3/min ・Max. static pressure:9.1 kPa~ 9.5kPa ・Collection efficiency: Min. 99.97% (for 0.3μm or larger particles) ・Rated voltage (50/60Hz): Single phase, 100VAC ・Max. intake temperature: +40℃ * Certificates/Approvals: EU RoHS2
Note

* Working temperature : 0 to +40℃
* Max. intake temperature : +40℃

Salient features
・Suctions fine airborne dust with a large volume of air like a vent fan For clean room use ・Max. air volume: 2.9m3/min ~7.0 m3/min ・Max. static pressure: 2.5kPa ~2.9kPa ・Collection efficiency: Min. 99% (for 0.3μm or larger particles) ・Rated voltage (50/60Hz): Single phase, 100VAC ・Max. intake temperature: +40℃ * Certificates/Approvals : EU RoHS
Note

* Working temperature : 0 to +40℃
* Max. intake temperature : +40℃

Salient features
  • The Pin stuck out center of terminal barrel to fit smoothly in narrower terminal block. Insulation cap (UL94V-0) for each Pin terminal are available.
  • Voltage : 600V/20A
Non-insulated Pin terminals NICHIFU (NCF), Part Numbers:
  • TC 0.3-9.5, TC 1.25-11, TC 1.25-11S, TC 1.25-16, TC 1.25-16S, TC 1.25-20, TC 1.25-20S, TC 2-11, TC 2-11S, TC 2-16, TC 2-16S, TC 2-20, TC 2-20S, TC 3.5-11S, TC 5.5-11
  • TC 0.75-13.5K-ST, TC 1.25-11S-ST, TC 1.25-11V-ST, TC 1.25-16V-ST, TC 1.25-18S-ST, TC 1.25-20S-ST, TC 2-11V-ST, TC 2-16V-ST, TC 2-18V-ST, TC 5.5-15-ST, TC 5.5-21-ST, TC 8-18-ST
  • TC 8-S-C, TC 8-C, TC 14S-C, TC 14-C, TC 22S-C, TC 22-C, TC 38-C, TC 60-C
  • TC 1.25-13.5V-ST-C, TC 1.25-16V-ST-C, TC 1.25-18S-ST-C, TC 2-13.5V-ST-C, TC 2-16V-ST-C, TC 2-18V-ST-C, TC 5.5-15-ST-C, TC 5.5-21-ST-C, TC 8-18-ST-C, TC 235-16S-C
Non-insulation VC CAP NICHIFU (NCF), Part Numbers:
  • VC 8, VC 14, VC 22S, VC 22, VC 38, VC 60
Note

Environmentally friendly insulated terminals, NICHIFU (NCF):

  • TMEX TC-0.3-9.5, TMEX TC-1.25-11, TMEX TC-1.25-11S, TMEX TC-1.25-16, TMEX TC-1.25-16S, TMEX TC-1.25-20, TMEX TC-1.25-20S, TMEX TC-2-11, TMEX TC-2-11S, TMEX TC-2-16, TMEX TC-2-16S, TMEX TC-2-20, TMEX TC-2-20S, TMEX TC-5.5-11

APPLIANCE ELECTRICAL WIRING

INSULATED CENTER PIN TERMINALS_NICHIFU

Salient features
Makes stranded wire to single to be fittable to push-on terminal block or switch. Wider entry type for two wires also available.  
Note

MATERIAL : Oxygen free copper tube.
(electro-tin-plated)
INSULATOR:NYLON
RATED VOLTAGE : 300V
INSULATOR TEMPERATURE : -40℃〜 +105℃

Salient features
Autonomous Intelligent Vehicles (AIVs) assist with routine, labor intensive material handling tasks
Note

Mobile Robots
LD / HD Series
Autonomous Mobile Robots (AMRs), self-mapping, self-navigating